Protein Purification System、Protein Purifier、AKTA Purifier、Cytiva Purifier
Firin Plus is a range of flexible, customer-friendly chromatography systems for the rapid purification of target products such as proteins, peptides and nucleic acids from micrograms to tens of grams. Firin Plus is also a reliable system whose hardware and CHIRON(Kirin) software are designed to work with chromatographic columns and chromatographic fillers to solve purification problems.
System characteristic
1.Modular system design, there are a variety of options, can be flexibly applied in the purification of proteins and peptides and other biological molecules;
2.The use of CHIRON software can be intuitive and flexible method creation, system control and result analysis;
3.The size is practical, easy to place in the laboratory workbench or freezer;
4.Continued the ACHROM system proven mature design, to ensure that the protein purification process is reliable;
5.Predefined method Settings for all conventional laboratory scale chromatographic columns.
System specification
Control system software: CHIRON 2.0 or higher
Power supply, instrument: 240V, 50/60HZ, maximum voltage fluctuation ±10% of rated voltage
Size, instrument: 560*663*516mm(W * H * D)
Noise level: <60 dB
Weight, instrument: approx. 60kg (instrument only)
Working environment: 4℃ to 35℃, no condensate
Standard component configuration
System pump
Pump type: Dual plunger pump dual pump
Flow range:0.01-150ml/min, 5MPa
0.01-100ml/min,10MPa
0.001-36ml/min,20MPa
Velocity accuracy:±2%
Viscosity range:0.7-10 cp
Valve group
Sampling valve: Manual loading/injection/direct injection/system pump waste/sample pump load/sample pump waste
Collection valve: three-way collection valve/multi-way collection valve
Pressure sensor
System pressure sensor
Detection range: 36ml system 0-20MPa
100ml system 0-10MPa
150ml system 0-5MPa
Detection accuracy: ±0.02MPa or ±2%, whichever is greater
Conductance detector
Detection range: 0.001-999.99mS/cm
Flow pool volume: 15μL
Temperature detector reading value: 0℃-99℃
Temperature detector accuracy: ±1.5℃, 4℃~45℃ range
Conductivity accuracy: ±0.01mS/cm or ±2%, whichever is greater (within 0.3~300mS/cm)
Ultraviolet detector
Dual wavelength detection: 280&254nm fixed dual wavelength detection
Multi-wavelength detection: 200-800nm detection of any four wavelengths
Flow pool range: Standard 2mm(optional)
Flow pool volume: 20μL
Uv drift: ±1mAU/Hr
Wavelength accuracy: ±1nm
Uv noise: ±0.2mAU
Mixer
Mixing principle: magnetic stirring, dynamic mixing
Mixing pool volume
36ml system: Standard 2ml, optional 0.6ml or 5ml
100/150ml system: standard 2ml, optional 5ml or 15ml
Optional component configuration
pH detector
Detection range: 0-14, effective range 2-12
Detection accuracy: ±0.1
Working pressure: 0-0.6Mpa(6bar, 87psi)
Pressure sensors (front and rear pressure sensors)
Detection range: 36ml system 0-20MPa
100ml system 0-10MPa
150ml system 0-5MPa
Detection accuracy: ±0.01Mpa(0.1bar, 1.45psi)
Component collector
Collection quantity: up to 144
Tube type: 13mm (5ml centrifugal tube 144)
18mm (15ml centrifugal tubes 72)
1.5ml (60 1.5ml centrifugal tubes)
50ml (36 50ml centrifugal tubes)
Dimensions: 31*33*37cm(length * width * height)
Weight: 5kg
Valve group
Buffer valve: three way valve/eight way valve
Column valve: five-column valve, positive and negative flow bypass
Collection valve: 12-way collection valve
Component configuration | Equipment Model | Premium 150 | Premium 100 | Premium 36 |
System pump | 0.01-150ml/min 5MPa | ◎ | ||
0.01-100ml/min 10MPa | ◎ | |||
0.001-36ml/min 20MPa | ◎ | |||
Ultraviolet detector | 200-800nm Real-time four-wavelength detection | ◎ | ◎ | ◎ |
280&254nm Fixed dual wavelength detection | ○ | ○ | ○ | |
Electrical conductivity detector | 0.001-999.99ms/cm | ◎ | ◎ | ◎ |
PH detector | 0-14, Effective detection range 2-12 | ○ | ○ | ○ |
Pump front buffer valve | Three-way valve / Octopus valve | ○ | ○ | ○ |
Sample valve | Manual loading/injection/direct injection/system pump waste fluid Sample pump loading/sample pump waste liquid | ◎ | ◎ | ◎ |
Column valve | Five-post valve | ○ | ○ | ○ |
Collecting valve | Multi-way collection valve (Waste liquid, component collector, 10 outlet locations) | ○ | ○ | ○ |
Mixer | Mixing pool size 2ml(optional) | ◎ | ◎ | ◎ |
Collector | X/Y axis positioning collection, collection rack is optional | ○ | ○ | ○ |
Anteroposterior column Pressure sensor | 36ml System range 0-20MPa | ○ | ○ | ○ |
100mlSystemrange0-10MPa | ||||
150ml System range 0-5MPa |
◎Is standard configuration, ○Is optional configuration